Alternate identifier:
-
Related identifier:
-
Creator/Author:
Kettner, Cagla https://orcid.org/0000-0003-4283-281X [Insititute of Sports and Sports Science, Karlsruhe Institute of Technology]

Stein, Thorsten https://orcid.org/0000-0002-7885-7085 [Insititute of Sports and Sports Science, Karlsruhe Institute of Technology]
Contributors:
(Researcher)
Beyerlein, Melina https://orcid.org/0009-0000-9974-5368 [Insititute of Sports and Sports Science, Karlsruhe Institute of Technology]

(Researcher)
Marquardt, Charlotte https://orcid.org/0000-0002-5757-1512 [Institute for Anthropomatics and Robotics, Karlsruhe Institute of Technology]

(Researcher)
Dežman, Miha https://orcid.org/0000-0001-7160-749X [Institute for Anthropomatics and Robotics, Karlsruhe Institute of Technology]

(Researcher)
Asfour, Tamim https://orcid.org/0000-0003-4879-7680 [Institute for Anthropomatics and Robotics, Karlsruhe Institute of Technology]
Title:
Data for "Ankle exoskeleton assistance increases task-relevant variability without altering center of mass control during walking"
Additional titles:
-
Description:
(Abstract) Ankle exoskeletons alter joint kinematics during walking, yet their effects on whole-body coordination remain unclear. This study investigated how ankle exoskeleton assistance influences the structure of motor variability and center-of-mass movement during steady-state walking.

(Technical Info) Twenty healthy adults walked on a treadmill at 1.1 m/s without the exoskeleton (noExo) and with active exoskeleton assistance (Exo). Whole-body kinematics were recorded. Variability was analyzed using the Uncontrolled Manifold (UCM) approach. Joint angle variability was decomposed into components th...

(Table Of Contents) o Raw data o Fully labeled data o Methods are described in the referred paper
Keywords:
Coordination
Exoskeleton
Gait
Joint variability
Motor control
Uncontrolled manifold
Related information:
-
Language:
English
Version:
-
Production year:
Subject areas:
Sports
Life Science
Resource type:
Dataset
Data source:
(Instrument) Infrared camera-based motion capturing: Vicon Motion Systems; Oxford Metrics Group, Oxford, UK; 10 Vantage V8 and 6 Vero V2.2 cameras; 200 Hz
Software used:
Resource production
Software:
Vicon Nexus - 2.16
Alternative software:
-
Data processing:
-
Publication year:
Rights holders:
Funding:
-
Name Storage Metadata Upload Action
Status:
Published
Uploaded by:
c97b74e0a3438db2d4b0806e428161e2
Created on:
Archiving date:
2026-11-16
Archive size:
12.2 GB
Archive creator:
bdbf2619140df79398807b21caa53e90
Archive checksum:
9250532354cf9359ab281064c75950c9 (MD5)
Embargo period:
-